Characteristics
Features
Connector Pin Assignments
|
|
|
|
|
|
TRIG_STOP | Edge Triggered Stop Input: A contact closure between this pin and the GND pin stops the pulse train output which was initialized by TRIG_START input. It will not stop the pulse train output if LEVEL_START is active. Deceleration will take place and the motor will stop when the speed decreases to the start/stop speed. |
|
|
TRIG_START | Edge Triggered Start Input: A contact closure between this pin and the GND pin starts the output pulse train with acceleration. It may be stopped by either of the two stop inputs: Trig_stop or Level_stop. |
|
|
LEVEL_START | Level Start Input: A contact closure between this pin and the GND pin will start the output pulse train with acceleration. The pulse train will run as long as this input is active (LOW). When the contact is opened, deceleration will take place and the motor will stop at the start/stop speed. This input can only be stopped by the LEVEL_STOP input or by opening the contact. If the LEVEL_STOP is used, the motor will stop without decelerating to the start/stop speed. |
|
|
SCAN | START SCAN MOVE Input: A contact closure between this pin and the GND pin starts the output pulse train with acceleration. The output pulse frequency will increase until the scan frequency is achieved. When released, deceleration will take place and will stop at the start/stop frequency. |
|
|
LEVEL_ STOP | Level Stop Input: A contact closure between this pin and the GND pin will stop the pulse train output initialized by SCAN, TRIG_START or LEVEL_START inputs without deceleration. If it is used to stop SCAN or LEVEL_START inputs, the pulse train output will resume once the LEVEL_STOP input is released. |
|
|
DIR_INPUT | Direction Input: The motor will rotates in one direction when this pin is open and will rotate in the other direction when this pin contacts with the GND pin. |
|
|
VOLT _IN | Analog input (0 ~ Vin - 4): If pin 1 & pin 2 of jumper 2 are connected, the Analog Input is enabled and the output pulse train frequency is proportional to the input voltage. |
|
|
PULSE OUTPUT | Pulse train output terminal (open collector output, SN74S08, Max20 mA) |
|
|
DIR OUTPUT | Direction output terminal (open collector output, SN74S08, Max 20 mA) |
|
|
+ 5V | +5 VDC output terminal (Max 200mA) |
|
|
GND | Ground ( Power Input Common ) |
|
|
GND | Ground ( Power Input Common ) |
|
|
Power Input | Power Input: 8 - 24 VDC power input terminal. |