Motor Specifications |
|
Driver Specifications |
|
|
|
|
UPS50-031 |
UPS50-131 |
|
Accuracy |
± 5 min. |
|
Output Current |
0.75 A per Phase Max. |
1.4 A per Phase Max. |
|
Shaft Radial Play |
0.00098 in. max. / 1.1
lbs load |
|
Driver Type |
Star Bi-Polar , Constant
Current Chopper |
|
Shaft Axial Play |
0.00295 in. max. / 2.2
lbs load |
|
Power Requirements |
90 - 121 VAC , 50/60 Hz |
|
Dielectric Strength |
No abnormality detected
after the application of 0.5KV at 50 Hz between motor windings
and frame for duration of one minute. |
|
Power Consumption |
2.0 A or less |
3.5 A or less |
|
Insulation Class |
Class B |
|
Built in Functions |
Auto Current Down at stand
still. Current OFF. Monitor Timing Output signal. Driver Overheat
warning signal output. |
|
Insulation Resistance |
100 ohms or better with
500V potential applied between motor windings and frame at normal
ambient temperature and humidity. |
|
Input Pulse Type |
Step & Direction or
Bi-Clock (CW/CCCW) pulses (Selectable). All Opto-Isolated . Voltage
H=4.5 to 5V , L = 0 to 0.5V , Resistance = 220 ohms. |
|
Operating Environment Temperature |
0 °
C to +50 ° C |
|
Dielectric Strength |
No abnormality detected
after the application of AC 1 KV between case and power input
terminals, case and signal I/O terminals, signal I/O terminals
and power input terminals for duration of one minute. |
|
|
|
Insulation Resistance |
100 M ohms or better with
500V potential applied between case and power input terminals
and signal I/ O terminals. |
|
|
|
Operating Environment Temperature |
0 °