UPS 53 PulStar V Series , High Speed Version
5-Phase, 5-Lead Stepping Motor and Driver Units

Very High Torque in a Compact package.
Selectable Resolution.
-- 0.72°/Full Step (500 step/rev)
-- 0.36°/Half Step (1000 step/rev)
Extremely smooth operation.
-- Virtually no low rpm resonance.
Motor and Driver are matched pair..
-- No current adjustments needed.
Unit includes Motor & Driver with Built-in Power Supply.
Highly cost effective.

 

 
UPS 53 Series
(A) after the Part Number denotes single shaft (Front shaft only) motor configuration.
(B) after the Part Number denotes thru shaft (Front & Rear shaft) motor configuration.

Motor Size(mm)

Motor and Driver Combination Part Number

Max. Holding Torque: oz-in (kg-cm)

Rotor Inertia oz-in2 (g-cm2)

Step Angle Full/Half

Phase Current (A)

Motor Weight: oz (kg)

Driver Part Number

Motor Part Number
Metric 23(60)
UPS53-569HAC(BC)
230.5(16.60)
2.80(560)
0.72°/0.36°
2.8
45.80(1.3)
UPS53-331
PF566HAC(BC)
Metric 34(85)
UPS53-596HAC(BC)
UPS53-599HAC(BC)
UPS53-5913HAC(BC)
291.6(20.9)
568.0(40.9)
873.5(62.9)
7.00(1400)
13.5(2700)
20.0(4000)
0.72°/0.36°
0.72°/0.36°
0.72°/0.36°
2.8
2.8
2.8
52.90(1.50)
88.20(2.50)
123.4(3.50)
UPS53-331
UPS53-331
UPS53-331
PF596HAC(BC)
PF599HAC(BC)
PF5913HAC(BC)

 

 

Motor Specification

 

Driver Specification

        UPS53-331
Accuracy ± 3 min.   Output Current 2.8 A per Phase Max.
Shaft Radial Play 0.025 mm. max. / 0.5 Kg load   Driver Type Star Bi-Polar , Constant Current Chopper
Shaft Axial Play 0.075 mm. max. / 1.1 Kg load   Power Requirements 85 - 132 VAC , 50/60 Hz
Dielectric Strength No abnormality detected after the application of 0.5KV at 50 Hz between motor windings and frame for duration of one minute.   Power Consumption 7.0 A or less
Insulation Class Class B   Built in Functions Auto Current Down at stand still. Current OFF. Monitor Timing Output signal. Driver Overheat warning signal output.
Insulation Resistance 100 ohms or better with 500V potential applied between motor windings and frame at normal ambient temperature and humidity.   Input Pulse Type Step & Direction or Bi-Clock (CW/CCCW) pulses (Selectable). All Opto-Isolated . Voltage H=4.5 to 5V , L = 0 to 0.5V , Resistance = 220 ohms.
Operating Environment Temperature 0 ° C to +50 ° C   Dielectric Strength No abnormality detected after the application of AC 1 KV between case and power input terminals, case and signal I/O terminals, signal I/O terminals and power input terminals for duration of one minute.
      Insulation Resistance 100 M ohms or better with 500V potential applied between case and power input terminals and signal I/ O terminals.
      Operating Environment Temperature 0 ° C to +40 ° C