| Model |
IMS51-110 |
IMS51-120 |
IMS51-210 |
IMS51-220 |
| Input
Voltage |
Single Phase
AC 100~120V ±10% 50/60 Hz |
Single Phase
AC 200~220V ±10% 50/60 Hz |
Single Phase
AC 100~120V ±10% 50/60 Hz |
Single Phase
AC 200~220V ±10% 50/60 Hz |
| Power
Consumption |
400VA or less |
500VA or less |
650VA or less |
850VA or less |
| Driver
Type |
Star Bi-Polar Type |
| Phase
Current |
1.4A/Phase |
2.8A/Phase |
| Resolution |
Basic step = 0.72 (Full Step, Half Step) |
| Build In
Functions |
Auto-current down at standstill (Except IMS51-120),
Auto-current OFF, Excitation timing signal output Driver overheat warning signal output. |
Auto-current down at standstill, Auto-current OFF, Excitation timing signal output Driver overheat warning signal output. |
| Signal
Input |
Photo-coupler Input : Input resistance 390 ohms Input signal voltage: L:0-0.5V, H:4-5V. STEP and DIRECTION or CW/CCW pulse (selectable). All Opto-isolated. |
| Signal
output |
Photo-coupler open collector output, Limited Capacity 25V
10mA or less, MONI, HEAT |
| Insulation
Resistance |
100M ohms or higher with DC500V Meger applied in normal
temperature and humidity. |
| Operating
Temperature |
0°C to +40°C / 32°F to 140°F |
| Size |
165 x 126 x 50 mm |
| Weight |
1000 Grams |