MPG1020 Two Axis Pulse Generator Chip, Ultra High Speed
Description

        The MPG1020 Pulse Generator chip is a DSP type peripheral circuit with built-in functions for Motion Control applications. The MPG1020 can control 2 Axes Stepping motors as well as Digital Input Servo motors. Address and Data commands sent directly to this Pulse Generator chip allow a system designer the flexibility of composing Trapezoidal , Triangular well as Velocity movement profiles for Open loop applications.

 

Features
  • Single Chip to Control the Motion of 2 Axes Stepping or Digital Input Servo Motors.
  • Capable of modify the Acceleration and Deceleration rates in order to provide Trapezoidal , Triangular and Velocity move profiles for Point to Point applications.
  • Ultra High Speed Pulse Rate output up to 7.5 Mhz.
  • Starting point for Deceleration can be calculated automatically.
  • Individual settings for Acceleration and Decelerations slopes.
  • Four Interrupts are provide for system or user intervention.
  • Desolation Micro-Step data output for 2-phase stepping motors (D/A transferable)
Specifications
Items Description
Power Requirement +5V ± 5%
Reference Clock 131 Khz ~ 14.5 Mhz
Pulse Range 1 ~ 16,777,215
Deceleration Starting Point Range 1 ~ 16,777,215
Frequency Resolution 65,536 steps within a given Output Frequency range
Acceleration or Deceleration Slope Resolution 65,536 steps within a given Output Frequency range
N-Division, Clock Divisions 256 steps
Maximum Output Frequency 0.004 ~ 256 Hz ( CLK = 131 Khz , n = 256 )

1 ~ 65,535 Hz ( CLK = 8 Mhz , n = 61 )

110 ~ 7,250,000 ( CLK = 14.5 Mhz , n = 1)

Operations and Functions Trapezoidal , Triangular or Velocity profiles. Automatic calculation of Deceleration starting point. Forward and Reverse limits, Home Return, Emergency Stop, Slow down Stop, Pulse Output end control and Emergency Stop for Servo’s motors. I/O signal Logic setting as well as Velocity, Acceleration and Deceleration settings.
Driver Interface Output Clock ˝ Clock Switching Setting
Input Alarm Active H/L Logic Setting
In Position Active H/L Logic Setting
Deviation Counter Overflow Active H/L Logic Setting
Sensor Inputs Forward Limit Active H/L Logic Setting
Reverse Limit Active H/L Logic Setting
Near Home Active H/L Logic Setting
Home Active H/L Logic Setting
Special Purpose Inputs Inputs Decel, Decel Stop, Immediate Stop
Operating Temperature 0 ~ + 50° C
Storage Temperature -60 ~ +150° C
Device Package 64 Pin QFP

Lead Pitch : 0.5mm

   